Vapor-compression chiller smart system

General Introduction

Vapor-compression chiller smart system is a substitution for electrical panel of Vapor-compression chiller order circuit by which chiller capacity is used based on building cooling load. This need is recognized by installed sensors on chiller and also out of building. Capability of scheduling for the building, used part time, causes power consumption reduction in addition to reduction of compressors’ depreciation and heating welfare providing.

One of this system’s advantages is chiller fault detection that after installation of this system, the device repairman can see the possible faults on the control system monitor without technical considerations.

How is energy consumption saving achieved thanks to chiller smart system operation?

  • Smart control of circulatory cold water inside the building ( fancoils, … ) based on building requirement
  • Control of on and off time of compressors based on building requirement and as result, reduction of compressors operation time and not turning on in unnecessary situations.

Technical specifications

Equipment and capabilities
  • Control of turning on way of compressors to reduce system’s initial start ampere.
  • Using air conditioning line pumps (fancoil and air conditioner pumps).
  • Using cooling tower line pumps and fans based on system requirement.
  • Time control based on weekdays for the building that are used part time and as result, reduction of consumption costs.
  • Preset up and acceleration of automatic turning off system for interrupted operations in buildings which are used part time.
  • Fault detection system to find out possible faults of the chiller and it causes unnecessary fault detection in time of being off, maintenance costs reduction and increase of supporting services.
  • According to fault detection, using substitutes in the time facing fault in the chiller to prevent chiller to be off.
  • Having system of operation data saving including temperature, equipment on and off states and giving required graphs and as result, analysis of device state and possible fault detection.
Device Input and output

This system is able to control two chillers that each one has 2 cooling cycle with following specification:

A) Digital Output

  • 5 PCS Compressor with 2 cycle
  • 6 PCS Unloader
  • 2 PCS Solenoid Valve
  • 3 PCS Circulating Pump (Fan coil and …)
  • 3 PCS Circulating Pump (Cooling Tower)
  • 2 PCS Cooling Tower Fan

B) Digital input

  • 5 PCS High Pressure Controller
  • 5 PCS Oil Pressure Controller
  • 5 PCS BiMetal  Controller
  • 2 PCS Low Pressure Controller
  • 2 PCS Flow Switch Controller
  • 1 PCS Anti Freeze Controller
  • 1 PCS Phase Control

C) Numbers and location of sensors

  • Thermal sensors in the section of output evaporator water
  • Thermal sensors in the section of input evaporator water
  • Thermal sensors in the section of output condenser water
  • Thermal sensors in the section of input condenser water
  • Thermal and humidity sensor installed outdoor ( a wireless sensor)
Central Machine Technical Specifications

ابعاد دستگاه مرکزی 20*12*9 (cm) Main Box Dimensions
وزن خالص دستگاه مرکزی 884 (gr) Net Weight (Main Box)
قابلیت عملکرد دستگاه در رطوبت محیط 85% Operating Relative Humidity
قابلیت عملکرد دستگاه در دمای محیط -20 ~ +50 ºC Operating Temperature
نوع خروجی های دیجیتال / اتصال Relay (16 Amp.) / Phoenix Type of Digital Output / Connection
توان خروجی های دیجیتال 5 ~ 6 Amp. Digital Output Current
تعداد خروجی های دیجیتال 24 pcs Quantity of DO Terminal
تعداد ورودی های دیجیتال 21 pcs Quantity of DI Terminal
نوع سنسورهای دما (حساسیت) Digital (0.01 ºC) Thermal Sensor Type (Sensitivity)
 نوع اتصال سنسورهای دما Wire : RJ45 – Wireless : RF Type of Thermal Sensor Connection
 بسترهای ارتباطی LAN (Internet – Ethernet) & RF (915 Mhz)

USB (Flash Memory)

Communication Systems
پروتکل های قابل پشتیبانی

در شبکه اینترنت و اترنت

 TCP,UDP,ICMP,IPV4 ARP,IGMP, PPPOE,ETHERNET AND SUPPORT ADSL, CONNECTION WITH SUPPORT PPPOE PROTOCOL WITH PAP/CHAP, (AUTHENTICATION MODE)

DHCP AND DNS

STANDARD CODE OF DESIGN: IEE802.3

SUPPORTED PROTOCOLS

(Internet and Ethernet)

نوع ساختار شبکه Web Server – Web Service
 نمایشگر 64 * 128 Dot Matrix Display
حافظه جانبی Life Time (Min 20 Years) : Including Temp., On-Off time, Error and etc With Graph Data Logger
ساخته شده Behsaz Energy (Islamic Republic of IRAN) Made By

Wireless Sensor Specifications

 ابعاد دستگاه مرکزی cm) 10.5*6.5*4)  Main Box Dimensions
 وزن خالص دستگاه مرکزی 168(gr)  (Net Weight (Main Box
 قابلیت عملکرد دستگاه در رطوبت محیط  85%  Operating Relative Humidity
 قابلیت عملکرد دستگاه در دمای محیط  -20 ~ +50 ºC  Operating Temperature
 نوع سنسورهای دما (حساسیت) ( Digital (0.01 ºC  (Thermal Sensor Type (Sensitivity
 نوع اتصال به سنسور دما  RJ45  Type of Thermal Sens Connection
 نمایشگر  7 Segment   Display
 بسترهای ارتباطی  (RF (433-915 Mhz  Communication Systems
 ساخته شده  (Behsaz Energy (Islamic Republic of IRAN  Made By

Special Facilities and Features

Chiller fault detection chiller without requiring a technician

15-40 % reduction of Vapor-compression chiller power consumption

Including USB port to connect Flash Memory

Substituting in chiller order circuit and reduction of possible fault

Precise control and stabilization of building inside temperature

Including LAN port, capable to connect INTERNET and ETHERNET under TCP-IP protocol capable of distance controlling and monitoring

Title

Certificates and Confirmations

Certificate of Competence Qualification
Fuel Conservation Company and Fuel Conservation Community

Fuel Conservation Company’s Confirmation
Patent Certificate
Certificate of Installations Industry Community
Certificate of Operation Quality and Supporting Services
Organization for Renovating, Developing and Equipping Schools of East Azarbaijan Province
Call and Implementation of Technical Topics Proceedings between Manufacturers
Organization for Renovating, Developing and Equipping Schools of East Azarbaijan Province
Confirmation as the Only Capable Company for Implementing the Considered Technical Specifications
Organization for Renovating, Developing and Equipping Schools of East Azarbaijan Province
Contractors’ Competence Certificate
Tehran Municipality Environment Department
Contractors’ Competence Certificate
Tehran Municipality Environment Department
Certificate of Satisfaction
District 13 Municipality
Introduction letter of Tehran City Council
Introduction letter of Tehran City Council
Certificate of Satisfaction and Conservation
Imam Khomeini Relief Foundation
Certificate of Satisfaction and Conservation
Residential Building
Certificate of Satisfaction and Conservation
Residential Building
Certificate of Satisfaction and Conservation
Residential Building
Certificate of Satisfaction and Conservation
Residential Building
Introduction Letter to Behsaz Energy Company for Installation and Testing of Mechanical Room Smart System in Organization
for Renovating, Developing and Equipping Schools of Tehran Province
Efficiency Confirmation from Organization for Renovating, Developing and Equipping Schools of Tehran Province
Introduction Letter of Fuel Conservation Company
To install Mechanical Room Smart System in Ministry of Interior
Introduction Letter of Fuel Conservation Company
To install Mechanical Room Smart System in Islamic Republic of Iran Air Force (IRIAF)
Choosing Behsaz Energy Among the Top 100 Companies in 1390(2011)
Certificate of Operation Quality for Monitoring and Control System
Organization for Renovating, Developing and Equipping Schools of East Azarbaijan Province
Résumés

Download

Vapor-compression chiller smart Catalogue
video